Technical Specifications
- Wavelengths: 850 nm, 1300 nm - Compatible fiber types: 50/125 µm, 62.5 µm - OTDR Port Connector: Cleanable UPC ferrule with removable SC adapter - Event dead zone 1: 850 nm: 0.5 m (typical), 1300 nm: 0.7 m (typical) - Attenuation dead zone 2: 850 nm: 2.5 m (typical), 1300 nm: 4.5 m (typical) - PON Dead Zone: N/A - Dynamic range 3,5, 6: 850 nm: 28 dB (typical), 1300 nm: 30 dB (typical) - Max distance range setting: 40 km - Distance measurement range 4, 5, 7, 8, 9, 10 :- 850 nm: 9 km, 1300 nm: 35 km - Reflectance range 4, 5: 850 nm: -14 dB to -57 dB (typical), 1300 nm: -14 dB to -62 dB (typical) - Sample resolution: 3 cm to 400 cm - Pulse widths (nominal): 850 nm: 3, 5, 20, 40, 200 ns, 1300 nm: 3, 5, 20, 40, 200, 1000 ns
|
General Specifications
- Operating temperature: -18º C to 45º C - Non-operating temperature: -30º C to 60º C - Operating altitude: 4,000 m (13,123 ft), 3,200 m (10,500 ft) with AC adapter - Storage altitude: 12,000 m - EMC: EN 61326-1 - FiberInspector probe specifications: • Magnification ~ 200X with OptiFiber Pro Display • Light source: Blue LED • Power source: Versiv Mainframe • Field of View (FOV) Horizontal: 425 µm, Vertical: 320 µm • Minimum detectable particle size: 0.5 µm -VFL specifications • On/Off control: Mechanical switch and a button on the touch screen • Output power: 316 µW (-5 dBm) = peak power = 1.0 mW (0 dBm) • Operating wavelength: 650 nm nominal • Spectral width: (RMS) ±3 nm
|